Panasonic Servo Drive Systems
With years of experience in the respective domain, we are engaged in offering Panasonic Servo Drive Systems, which are known for their durability and excellent performance. Based on latest technology, these systems ensure high performance and function with precision, smart control, safety and easy configuration. Available in various technical specifications, our range caters to the requirements of various industries.
| project | content |
|---|---|
| Order product number | AVF200-0072 |
| Model | AVF200-0072 |
| Standard motor output (kW) | 0.75kW |
| Rated output : Rated voltage | Single phase 200V~230V AC (supply voltage ratio) |
| Rated output : Overload current rating | 150% of rated output current for 1 minute |
| Input power supply: phase number, voltage, frequency | Single phase 200V~230V AC 50/60Hz |
| Input power : Voltage is allowed to vary | +10%, -15% of rated input AC voltage |
| Input power : Frequency allowed to vary | ±5% of rated input frequency |
| Input power : Transient voltage drop tolerance | It continues to operate above 165V AC and continues to operate for 165ms when it drops below 15V AC |
| Output Frequency : Frequency range | 0.5Hz~400Hz |
| Output Frequency : Frequency display | Digital display |
| Output Frequency : Frequency accuracy | Analog setting: Maximum set frequency± within 0.5% (25°C±10°C) Digital setting: maximum set frequency± within 0.01% (-10°C~+50°C) |
| Output Frequency : Frequency resolution | Digital setting: 0.1Hz Analog setting: 0.1Hz (in 50/60Hz mode) |
| Inverter control mode | High carrier frequency sine wave PWM control (optional V/F control, simple vector control) |
| Carrier frequency | V/F control setting: 7 types can be selected (0.8Hz~10kHz variable) Simple vector control setting: 4 types (2.5Hz~10kHz variable) (0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10.0kHz) |
| Run : Run • Stop | Operation panel switch Selectable 1A contact signal, 3-wire input (1A, 1B contact signal) RS485 communication Standby time can be set (0.1 seconds ~ 100 seconds) |
| Run : Forward or reverse | Operation panel switch 1A contact signal (can be set to prohibit inversion) RS485 communication |
| Run : Jog run | The operating frequency is arbitrarily set from 0.5Hz~400Hz, and the acceleration and deceleration time is set arbitrarily from 0.04 seconds ~ 3600 seconds |
| Run : Stop mode | Deceleration stop • Inertial stop (choose to switch) |
| Run : Reset function | Stop signal reset, external reset, panel reset (configurable) and power reset |
| Run : Start frequency | Set arbitrarily in 0.5Hz~60Hz |
| Run : Stop frequency | Set arbitrarily in 0.5Hz~60Hz |
| Run : Stop and start running again | Restart 0Hz, Restart Operating Frequency, Restart Speed Search (Select Toggle) |
| Run : Speed Search | Speed search at startup (configurable) |
| Run : Retry the function | Retry selection: function yes/no, retry abnormal content selection Number of re-attempts: 1~10 times arbitrary setting |
| Control : Frequency setting signal | Panel settings (operation panel): potentiometer, digital settings Analog setting signal for external operation: • Potentiometer (10kΩ, 1/4W or more) •0V-5V DC,0V-10V DC •4mA-20mA •0mA-20mA (with external resistors of 200Ω and 1/4W or more) External control operation digital setting signal: • PWM signal (signal period: 0.9ms~1100ms) • Frequency rise/decrease SW • Storage SW signal Communication setting: RS485 communication |
| Control : Voltage/frequency characteristics | Substrate frequency: fixed at 50Hz and 60Hz, set arbitrarily at 45Hz~400Hz 3-point V/F mode: set the voltage and frequency arbitrarily V/F curve: constant torque • reduced torque mode (select toggle) |
| Control : Torque boost | 0~40% arbitrary setting, automatic torque increase (optional) |
| Control : Acceleration and deceleration time | 0.04 sec. ~ 3600 sec. (individual settings for acceleration and deceleration) |
| Control : Acceleration and deceleration characteristics | Straight, S-type acceleration and deceleration (optional) |
| Control : 2nd function selection | Select the second function (acceleration and deceleration time, torque boost, voltage/frequency characteristics.) (Substrate frequency, 2-point V/F mode), electronic thermal sensitivity, analog frequency setting) |
| Control : Multi-speed frequency setting | • Multi-speed operation: up to 16 speed (arbitrary frequency) • Timer operation: up to 8 speed (arbitrary frequency) • Pulse input operation: up to 8 speed settings (arbitrary frequency) It can be linked to acceleration and deceleration times |
| Control : Frequency jump setting | Up to 3 settings (the frequency jump range is set arbitrarily between 1Hz~10Hz) |
| Control : Upper limit frequency setting | 0.5Hz~400Hz arbitrary setting |
| Control : Lower limit frequency setting | 0.5Hz~400Hz arbitrary setting |
| Control: Bias • gain frequency setting | Bias frequency: -99%~250% arbitrary setting Gain frequency: 0~500% arbitrary setting |
| Control : External stop function | External abnormal stop, inertial stop (optional) |
| Control : PID function | PID control mode (configurable) |
| Control : Auto-tune | Automatic tuning of motor constants |
| Control : Slip rate compensation control | Configurable |
| Control : Cooling fan ON/OFF control | Configurable |
| Control : Communication functions | • Interface: RS485 serial communication • Communication speed: 4800/9600/19200/38400 bps (optional) Protocol: MEWTOCOL-COM/Modbus (RTU) (optional) • Communication mode: half-duplex mode • Maximum number of connections: 31 • Maximum transmission distance: 500m (total wiring length) |
| Braking : Regenerative braking torque | •200V 0.2kW: 100% or more, 0.4kW: 80% or more, 0.75kW~2.2kW: 20% or more • 400V 0.75kW~15kW: 20% or more |
| Braking : DC braking | Actions below the stop frequency • Braking torque level: 0~100 (set 20 segments) • Braking time: 0.1 seconds ~ 120 seconds arbitrary setting |
| Output signal : Analog output | Output specification: 0V~10V DC (max. 1mA) Output function: Output frequency and output current ratio (optional) |
| Output signal: Open collector output | Output specifications: maximum rated 50V DC, 50mA Output functions: operating signal, arrival signal, overload alarm, frequency detection, reversal signal abnormal alarm, Current Sensing, Timer End Signal, Output Frequency/Current Ratio PWM Signal (1ms Period) (Selectable) |
| Output signal : Relay output | Output specification: 1c contact (contact capacity 230V AC, 0.3A resistance load) Output functions: running signal, arrival signal, overload alarm, frequency detection, inversion Signal abnormality alarm, current detection, timer end signal (optional) |
| Display : Running•Control Status | Output frequency, line speed display (optional), direction of rotation Output voltage, internal DC voltage, set frequency, communication station number, timer run times, alarm type, Control terminal status (input signal, output signal), operating status, PID (set value, measured value, output value), Autotune progression status Cumulative operating time, cumulative fan operating time |
| Display : Abnormal content | Display symbol when the protection function is active (abnormal content can be stored 4 times) |
| Protection : Current limit | The current limit function can be set at 1%~200% of the rated output current |
| Protection : Trip (stop) | Transient overcurrent (SC1-6), temperature abnormality (OH) Overcurrent (OC1-3), Overload & Electronic Thermal Relay (OL), Undervoltage (LU), Overvoltage (OU1-3), Cooling fan failure (FAN), external exception (AU), operation exception (OP), CPU error (CPU) |
| Protection : Stall prevention function | Prevent overcurrent stall and prevent overvoltage stall |
| Environment : Use ambient temperature and humidity | -10°C~+50°C (Note 1) (no freezing), 90%RH or less (no condensation) (Note 1): -10°C~+40°C for lateral tight installation. |
| Environment : Storage temperature and humidity | -25°C~+65°C, 95%RH or less |
| Environment : Vibration | 5.9m/s2 (0.6G) or less |
| Environment : Elevation | The elevation is below 1000m |
| Environment : Place of use | Indoors, should be free of corrosive gases, flammable gases, oil mist, dust |
| Protection Construct | IP20 in-disk mounting form |
| Cooling method | •200V 0.2kW~0.75kW: self-cooling, 1.5kW~2.2kW: air-cooled • 400V 0.75kW: self-cooling•1.5kW~15kW: air-cooled |
Panasonic MSD-EX SERIES
MSD043P1EA
MSD043P1EB
MSD043P1EC
MSD043P1ED
MSD043P1EE
MSD043P1EF
MSD043P1EG
MSD043P1EH
MSD043P1EI
MSD043P1EJ
MSD043P1EK
MSD043P1EL
MSD043P1EM
MSD043P1EN
MSD043P1EO
MSD043P1EP
MSD043P1EQ
MSD043P1ER
MSD043P1ES
MSD043P1ET
MSD043P1EU
MSD043P1EV
MSD043P1EW
MSD043P1EX
MSD043P1EY
MSD043P1EZ
IV.Similiar Servo Amplifier
MSDA3A1A1A
MSDA5A1A1A
MSDA011A1A
MSDA021A1A
MSDA041A1A
MSDA3A3A1A
MSDA5A3A1A
MSDA013A1A
MSDA023A1A
MSDA043A1A
MSDA083A1A
MSDA103A1A
MSDA153A1A
MSDA203A1A
MSDA253A1A
MSDA303A1A
MSDA353A1A
MSDA403A1A
MSDA453A1A
MSDA503A1A
MSDA3A1D1A
MSDA5A1D1A
MSDA011D1A
MSDA021D1A
MSDA041D1A
MSDA3A3D1A
MSDA5A3D1A
MSDA013D1A
MSDA023D1A
MSDA043D1A
MSDA083D1A
MSDA103D1A
MSDA153D1A
MSDA203D1A
MSDA253D1A
MSDA303D1A
MSDA353D1A
MSDA403D1A
MSDA453D1A
MSDA503D1A